HIP5600
WN ITHDRA PART W BSOLETE SS O PROCE IGNS W DES NO NE
September 1998
File Number
3270.7
Thermally Protected High Voltage Linear Regulator
The HIP5600 is an adjustable 3-terminal positive linear voltage regulator capable of operating up to either 400VDC or 280VRMS. The output voltage is adjustable from 1.2VDC to within 50V of the peak input voltage with two external resistors. This high voltage linear regulator is capable of sourcing 1mA to 30mA with proper heat sinking. The HIP5600 can also provide 40mA peak (typical) for short periods of time. Protection is provided by the on chip thermal shutdown and output current limiting circuitry. The HIP5600 has a unique advantage over other high voltage linear regulators due to its ability to withstand input to output voltages as high as 400V(peak), a condition that could exist under output short circuit conditions. Common linear regulator configurations can be implemented as well as AC/DC conversion and start-up circuits for switch mode power supplies. The HIP5600 requires a minimum output capacitor of 10F for stability of the output and may require a 0.02F input decoupling capacitor depending on the source impedance. It also requires a minimum load current of 1mA to maintain output voltage regulation. All protection circuitry remains fully functional even if the adjustment terminal is disconnected. However, if this happens the output voltage will approach the input voltage.
Features
* Operates from 50VDC to 400VDC * Operates from 50VRMS to 280VRMS Line * UL Recognized * Variable DC Output Voltage 1.2VDC to VIN - 50V * Internal Thermal Shutdown Protection * Internal Over Current Protection * Up to 40mA Peak Output Current * Surge Rated to 650V; Meets IEEE/ANSI C62.41.1980 with Additional MOV CAUTION: This product does not provide isolation from AC line.
Applications
* Switch Mode Power Supply Start-Up * Electronically Commutated Motor Housekeeping Supply * Power Supply for Simple Industrial/Commercial/Consumer Equipment Controls * Off-Line (Buck) Switch Mode Power Supply
Ordering Information
PART NUMBER HIP5600IS HIP5600IS2 TEMP. RANGE -40oC to +100oC -40oC to +100oC PACKAGE 3 Lead Plastic SIP 3 Lead Gullwing Plastic SIP
Pinouts
HIP5600 (TO-220) TOP VIEW
TAB ELECTRICALLY CONNECTED TO VOUT VOUT
HIP5600 (MO-169) TOP VIEW
HIP5600
VOUT
ADJ
VOUT
ADJ
63
VIN
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a registered trademark of Intersil Americas Inc. Copyright (c) Intersil Americas Inc. 2002. All Rights Reserved
VIN
HIP5600 Functional Block Diagram
RECTIFIER FOR AC OPERATION VIN
HIP5600
PASS TRANSISTOR
SHORT-CIRCUIT PROTECTION
VOUT
BIAS NETWORK C2 + + RF1
FEEDBACK OR CONTROL AMPLIFIER +
-
VOLTAGE REFERENCE
ADJ
Schematic Diagram
VIN D1 D2 Q1 Q2 D3 R3 R1 D4
R2
D7 D8
Q4 R4 Q5 R5 D5 C1 R7 Q3 R6 R8 Q7 R10 R9 ADJ Q8 Q6 Q10 D6 Q9
R11 Q14 R14 Q13 R15 VOUT
FIGURE 1.
64
-
C1
THERMAL SHUTDOWN
+
RF2
Q11 R12 Q12 R13 D9
HIP5600
Absolute Maximum Ratings
Input to Output Voltage, Continuous . . . . . . . . . . . . +480V to -550V Input to Output Voltage, Peak (Non Repetitive, 2ms) . . . . . . . 650V Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +150oC ADJ to Output, Voltage to ADJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V Storage Temperature Range . . . . . . . . . . . . . . . . . -65oC to +150oC Lead Temperature (Soldering 10s). . . . . . . . . . . . . . . . . . . . +265oC
Thermal Information (Typical)
Thermal Resistance Plastic SIP Package . . . . . . . . . . . . . . JA 60oC/W JC 4oC/W
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Operating Voltage Range . . . . . . . . . . . . . . 80VRMS to 280V RMS or 50V DC to 400VDC Operating Temperature Range . . . . . . . . . . . . . . . .-40oC to +100oC
Electrical Specifications Conditions VIN = 400VDC, IL = 1mA, CL = 10F, VADJ = 3.79V, VOUT = 5V (Unless Otherwise Specified) Temperature = Case Temperature. PARAMETER INPUT Input Voltage Max Peak Input Voltage Input Frequency (Note 1) Bias Current (IBIAS Note 2) REFERENCE IADJ IADJTC (Note 1) IADJ LOAD REG (Note 1) VREF (Note 3) VREF TC (Note 1) Line Regulation VREF LINE REG Load Regulation VREF LOAD REG PROTECTION CIRCUITS Output Short Circuit Current Limit Thermal Shutdown TTS (IC surface, not case temperature. Note 1) Thermal Shutdown Hysteresis (Note 1) NOTES: 1. Characterized not tested 2. Bias current input current with output pin floating. 3. VREF = VOUT - VADJ V IN = 50V VIN = 400V VIN = 400V +25oC 35 127 134 45 142 mA
oC
CONDITION
TEMP
MIN
TYP
MAX
UNITS
DC Non-Repetitive (2ms)
Full Full Full Full
50 DC 0.4
0.5
400 650 1000 0.6
V V Hz mA
+25oC IL = 1mA IL = 1mA to 10mA Full +25oC +25oC IL = 1mA 50VDC to 400VDC Full +25oC Full IOUT = 1mA to 10mA +25oC Full
50 1.07 -
65 +0.15 -215 1.18 -460 9 9 3 3
80 1.30 14.5 29 5 6
A A/oC nA/mA V V/oC V/V V/V mV/mA mV/mA
-
-
34
-
oC
65
HIP5600 Application Information
Introduction In many electronic systems the components operate at 3V to 15V but the system obtains power from a high voltage source (AC or DC). When the current requirements are small, less than 10mA, a linear regulator may be the best supply provided that it is easy to design in, reliable, low cost and compact. The HIP5600 is similar to other 3 terminal regulators but operates from much higher voltages. It protects its load from surges +250V above its 400V operating input voltage and has short circuit current limiting and thermal shutdown self protection features. Output Voltage The HIP5600 provides a temperature independent 1.18V reference, VREF , between the output and the adjustment terminal (V REF = VOUT - VADJ). This constant reference voltage is impressed across RF1 (see Figure 2) and results in a constant current (I1) that flows through RF2 to ground. The voltage across RF2 is the product of its resistance and the sum of I1 and IADJ. The output voltage is given in Equations 1(A, B).
V OUT = (V REF RF1 + RF2 ( RF2 ) ) ------------------------------ + I ADJ RF1
HIP5600 AC/DC VOUT ADJ VIN
VOUT(NOMINAL) 3.3V 4.9V 12.0V 14.8V
VREF IADJ I1 RF1 RF2 AC/DC
RF1 3.6k 2.7k 1.8k 1.1k
RF2 5.6k 7.5k 15k 12k
VOUT
FIGURE 2.
(EQ. 1A)
Example: Given: VIN = 200VDC , VOUT = 15V, IOUT = 2mA to 12mA, SA = 10oC/W, RF1 = 1.1k 5% low, RF2 = 12k 5% high, IOUT equals 10mA and Temp equals +60 oC (ambient temperature +25oC to +85oC). The worst case VOUT for the given conditions is -1.13V. The shift in VOUT is attributed to the following: -1.55V manufacturing tolerances, +1.33V external resistors, -0.62V load regulation and -0.29V temperature effects. Regulator With Zener
V
OUT
RF1 + RF2 = ( 1.18 ) x ------------------------------ + 65A ( RF2 ) RF1
(EQ. 1B)
HIP5600
VOUT = 1.18 + VZ VOUT 3.7V
VOUT AC/DC
VZ 2.5V 3.9V 9.1V 11V 15V
Error Budget

V OUT =
RF 1 + RF2 V T REF ------------------------RF1

RF2 + I T ADJ RF2 + I A DJ RF 2 -----------RF2
ADJ
VIN
5.1V 10.3V
R F2
R F1
Where;
T V RE F
V REF + V REF
LOA DREG
( I OUT ) + V REF TC ( Temp )
+V TC ( ) ( IOUT V IN ) + V REF SA REFLINEREG
I T ADJ I ADJ + I A DJ
+I ADJ TC (
LO ADRE G
( I OUT ) + IADJ TC ( Te mp )
SA
) ( I OUT V IN )
Note:
RFx = % tolerance of resistor x -------------RFx
Equations 2(A,B,C) are provided to determine the worst case output voltage in relation to; manufacturing tolerances (VREF and IREF),% tolerance in external resistors (RF1/RF1, RF2/RF2), load regulation (VREF LOAD REG , IADJ LOAD REG ), line regulation (VREF LINE REG) and the effects of temperature (VREFTC, IREFTC), which includes self heating (SA).
66

R F2 + V RE F --------R F1

R F2 RF1 ------------- - -------------
(EQ. 2A)
VREF IADJ
I1 RF1 VZ
12.2V
VOUT
16.2V RF1 = 10k
AC/DC
(EQ. 2B)
FIGURE 3.
(EQ. 2C)
The output voltage can be set by using a zener diode (Figure 3) instead of the resistor divider shown in Figure 2. The zener diode improves the ripple rejection ratio and reduces the value of the worst case output voltage, as illustrated in the example to follow. The bias current of the zener diode is set by the value of RF1 and IADJ. The regulator / zener diode becomes an attractive solution if ripple rejection or the worst case tolerance of the output voltage is critical (i.e. one zener diode cost less than one 10F capacitor (C3) and one 1/4W resistor RF2). Minimum power dissipation is possible by reducing I1 current, with little effect on the output voltage regulation. The output voltage is given in Equation 3. Equations 4(A,B, C) are provided to determine the worst case output voltage in relation to; manufacturing tolerances
HIP5600
V
OUT
= V REF + V Z
(EQ. 3)
Error Budget
V OUT = V T REF + V T Z V T REF V REF + V RE F
+V REF TC ( SA
HIP5600
HIP5600 AC/DC ADJ AC/DC
(EQ. 4A)
VOUT VOUT VIN
LOADREG
( I OUT ) + V REF TC ( Temp )
ADJ
) ( I OUT V IN ) + V
REFLINEREG
(EQ. 4B)
VREF
RS I1 RF1 RF2 AC/DC VREF VOUT IADJ
VIN I1
RS
V T Z V Z to l er an ce ( V Z ) + V Z TC ( Te mp )
(EQ. 4C)
RF1 RF2 AC/DC
VOUT
IADJ
of HIP5600 and the zener diode (VREF and Vz), load regulation of the HIP5600 (VREF LOAD REG), and the effects of temperature on the HIP5600 and the zener diode (VREFTC, VZTC). Example: Given: VIN = 200V, V OUT = 14.18V (VREF = 1.18V, VZ = 13V), VZ = 5%, VZTC = +0.079%/ C (assumes 1N5243BPH), IOUT equal 10mA and Temp equal +60 oC. The worst case VOUT is 0.4956V. The shift in VOUT is attributed to the following: -0.2 (HIP5600) and 0.69 (zener diode). The regulator/zener diode configuration gives a 3.5% (0.49/14.18) worst case output voltage error where, for the same conditions, the regulator/resistor configuration results in an 7.5% (1.129/15) worst case output voltage error. External Capacitors A minimum10F output capacitor (C2) is required for stability of the output stage. Any increase of the load capacitance greater than 10F will merely improve the loop stability and output impedance. A 0.02F input decoupling capacitor (C1) between VIN and ground may be required if the power source impedance is not sufficiently low for the 1MHz - 10MHz band. Without this capacitor, the HIP5600 can oscillate at 2.5MHz when driven by a power source with a high impedance for the 1MHz 10MHz band. An optional bypass capacitor (C3) from VADJ to ground improves the ripple rejection by preventing the ripple at the Adjust pin from being amplified. Bypass capacitors larger than 10F do not appreciably improve the ripple rejection of the part (see Figure 20 through Figure 25). Load Regulation For improved load regulation, resistor RF1 (connected between the adjustment terminal and VOUT) should be tied directly to the output of the regulator (Figure 4A) rather than near the load Figure 4B. This eliminates line drops (RS) from appearing effectively in series with RF1 and degrading regulation. For example, a 15V regulator with a 0.05 resistance between the regulator and the load will have a load regulation due to line resistance of 0.05 x IL. If RF1 is connected near the load the effective load regulation will be 11.9 times worse (1+R2/R1, where R2 = 12k, R1 = 1.1k).
(A)
FIGURE 4.
(B)
Protection Diodes The HIP5600, unlike other voltage regulators, is internally protected by input diodes in the event the input becomes shorted to ground. Therefore, no external protection diode is required between the input pin and the output pin to protect against the output capacitor (C2) discharging through the input to ground. If the output is shorted in the absence of D1 (Figure 5), the bypass capacitor voltage (C3) could exceed the absolute maximum voltage rating of 5V between VOUT and VIN . Note; No protection diode (D1) is needed for output voltages less than 6V or if C3 is not used.
VIN HIP5600 C1 0.02F D1 PROTECTS AGAINST C3 DISCHARGING WHEN THE OUTPUT IS SHORTED. + VOUT RF1 C3 10F D1 C2 10F
VOUT
ADJ
FIGURE 5. REGULATOR WITH PROTECTION DIODE
Selecting the Right Heat Sink Linear power supplies can dissipate a lot of power. This power or heat must be safely dissipated to permit continuous operation. This section will discuss thermal resistance and show how to calculate heat sink requirements. Electronic heat sinks are generally rated by their thermal resistance. Thermal resistance is defined as the temperature rise per unit of heat transfer or power dissipated, and is expressed in units of degrees centigrade per watt. For a particular application determine the thermal resistance (SA) which the heat sink must have in order to maintain a junction temperature below the thermal shut down limit (TTS).
67
VIN RF2
HIP5600
A thermal network that describes the heat flow from the integrated circuit to the ambient air is shown in Figure 6. The basic relation for thermal resistance from the IC surface, historically called "junction", to ambient (JA) is given in Equation 5. The thermal resistance of the heat sink (SA) to maintain a desired junction temperature is calculated using Equation 6.
PD TJ = JUNCTION
Example, Given: VIN = 400VDC JC = 4.8oC/W TA = +50oC VREF = 1.18V
I
VOUT = 15V TTS = +127C RF1 = 1.1k
ILOAD = 15mA IADJ = 80A
P = 6.2W = (VIN - VOUT)(IIN )
I
JC
TC = CASE TS = HEAT SINK
IN
V REF ADJ + ------------------ + I LOAD RF1
CS SA
HEAT SINK
Find: Proper heat sink to keep the junction temperature of the HIP5600 from exceeding TTS (+127oC). Solution: Use Equation 6, (EQ. 7) (EQ. 8)
TA = AMBIENT AIR
-T T TS A SA = --------------------------- - JC P
FIGURE 6.

JA = --------------------P Where:
TJ - T A
C -------W
C 127C - 50C SA = ------------------------------------------ - 4.8C = 7.62 -------6.2 W
(EQ. 5) T =T J TS
JA = JC + CS + SA SA + Where: CS
and
T TS - T A SA = --------------------------- - JC P
The selection of a heat sink with SA less than +7.62oC/W would ensure that the junction temperature would not exceed the thermal shut down temperature (TTS) of +127xoC. A Thermalloy P/N7023 at 6.2W power dissipation would meet this requirement with a SA of +5.7xoC/W. Operation Without A Heatsink The package has a JA of +60oC/W. This allows 0.7W power dissipation at +85oC in still air. Mounting the HIP5600 to a printed circuit board (see Figure 39 through Figure 41) decreases the thermal impedance sufficiently to allow about 1.6W of power dissipation at +85oC in still air. Thermal Transient Operation For applications such as start-up, the HIP5600 in the TO-220 package can operate at several watts -without a heat sinkfor a period of time before going into thermal shutdown.
(EQ. 6)
JA = (Junction to Ambient Thermal Resistance) The sum of the thermal resistances of the heat flow path. JA = JC + CS + SA TJ = (Junction Temperature) The desired maximum junction temperature of the part. TJ = TTS TTS = (Thermal Shutdown Temperature) The maximum junction temperature that is set by the thermal protection circuitry of the HIP5600 (min = +127oC, typ = +134oC and max = +142oC). JC = (Junction to Case Thermal Resistance) Describes the thermal resistance from the IC surface to its case. JC = 4.8oC/W CS = (Case to Mounting Surface Thermal Resistance) The resistance of the mounting interface between the transistor case and the heat sink. For example, mica washer. SA = (Mounting Surface to Ambient Thermal Resistance) The resistance of the heat sink to the ambient air. Varies with air flow. TA = Ambient Temperature P = The power dissipated by the HIP5600 in watts. P = (VIN - VOUT)(IOUT) Worst case SA is calculated using the minimum TTS of +127oC in Equation 6.
PD = I IN (VIN - VOUT) TJ = JUNCTION 0.6JC DIE/PACKAGE INTERFACE 0.4JC TS = HEAT SINK OR CASE SA TA = AMBIENT AIR CS + 0.5CP 0.5C P CD
FIGURE 7. THERMAL CAPACITANCE MODEL OF HIP5600
Figure 7 shows the thermal capacitances of the TO-220 package, the integrated circuit and the heat sink, if used. When power is initially applied, the mass of the package absorbs heat which limits the rate of temperature rise of the
68
HIP5600
junction. With no heat sink CS equals zero and SA equals the difference between JA and JC. The following equations predict the transient junction temperature and the time to thermal shutdown for ambient temperatures up to +85oC and power levels up to 8W. The output current limit temperature coefficient (Figure 39) precludes continuous operation above 8W.

TJ ( t ) = TA + T1 + T2 + T3
-t -------
(EQ. 11A)
-t ---TJ ( t ) = TA + PJC + PSA 1 - e
Where: (EQ. 9)
Where:
SA ( C P + C S )
1 SA ( C P + C S )
-t -------
For the TO-220, CP is 0.9Ws to 1.1Ws per degree compared to about 2.6mWs per degree for the integrated circuit and C S is 0.9Ws per degree per gram for aluminum heat sinks. Figure 8 shows the time to thermal shutdown versus power dissipation for a part in +22oC still air and at various elevated ambient temperatures with a SA of +27oC/W from forced air flow. For the shorter shutdown times, the SA value is not important but the thermal capacitances are. A more accurate equation for the transient silicon surface temperature can be derived from the model shown in Figure 7. Due to the distributed nature of the package thermal capacitance, the second time constant is 1.7 times larger than expected.
10 2
Where: 3 0.6
C JC D
Thermal Shutdown Hysteresis Figure 9 shows the HIP5600 thermal hysteresis curve with VIN = 100VDC , VOUT = 5V and IOUT = 10mA. Hysteresis is added to the thermal shutdown circuit to prevent oscillations as the junction temperature approaches the thermal shutdown limit. The thermal shutdown is reset when the input voltage is removed, goes negative (i.e. AC operation) or when the part cools down.
10 HEATING
TIME TO THERMAL SHUTDOWN (s)
10 1
+22xoC IOUT (mA) +70xoC
8.0
6.0
10 0
+85xoC
4.0 COOLING 2.0
+100xoC 10-1 +115x oC +120 oxC 10-2 0.0 2.0 4.0 6.0 8.0 10 0.0 98.0 105.0 113.0 120 127 CASE TEMPERATURE (oC) 135 142
FIGURE 9. THERMAL HYSTERESIS CURVE
AC to DC Operation
Since the HIP5600 has internal high voltage diodes in series with its input, it can be connected directly to an AC power line. This is an improvement over typical low current supplies constructed from a high voltage diode and voltage dropping resistor to bias a low voltage zener. The HIP5600 provides better line and load regulation, better efficiency and heat
POWER DISSIPATION (W)
FIGURE 8. TIME TO THERMAL SHUTDOWN vs POWER DISSIPATION
69

T 0.6P 1 - e 3 3 JC

-t -------
SHUTDOWN REGION



P ( JC + SA ) + T - T A TS t = - ln -----------------------------------------------------------------PSA

(EQ. 10)
Where:
( 0.5C + C )0.5C P P S 2 0.7JC ----------------------------------------------------------CP + C S

T 2 0.4P JC 1 - e 2


T P 1 - e 1 1 SA

(EQ. 11B)

(EQ. 11C)
(EQ. 11D)
HIP5600
transfer. The latter because the TO-220 package permits easy heat sinking. The efficiency of either supply is approximately the DC output voltage divided by the RMS input voltage. The resistor value, in the typical low current supply, is chosen such that for maximum load at minimum line voltage there is some current flowing into the zener. This resistor value results in excess power dissipation for lighter loads or higher line voltages. Using the circuit in Figure 3 with a 1000F output capacitor the HIP5600 only takes as much current from the power line as the load requires. For light loads, the HIP5600 is even more efficient due to it's interaction with the output capacitor. Immediately after the AC line goes positive, the HIP5600 tries to replace all the charge drained by the load during the negative half cycle at a rate limited by the short circuit current limit (see "A1" and "B1" Figure 10). Since most of this charge is replaced before the input voltage reaches its RMS value, the power dissipation for this charge is lower than it would be if the charge were transferred at a uniform rate during the cycle. When the product of the input voltage and current is averaged over a cycle, the average power is less than if the input current were constant. Figure 11 shows the HIP5600 efficiency as a function of load current for 80VRMS and 132VRMS inputs for a 15.6V output. Referring again to Figure 10, Curve "A1" shows the input current for a 10mA output load and curve "B1" with a 3mA output load. The input current spike just before the negative going zero crossing occurs while the input voltage is less than the minimum operating voltage but is so short it has no detrimental effect. The input current also includes the charging current for the 0.02F input decoupling capacitor C1. The maximum load current cannot be greater than 1/2 of the short circuit current because the HIP5600 only conducts over 1/2 of the line cycle. The short circuit current limit (Figure 38) depends on the case temperature, which is a function of the power dissipation. Figure 38 for a case temperature of +100oC (i.e. no heat sink) indicates for AC operation the maximum available output current is 10mA (1/2 x 20mA). Operation from full wave rectified input will increase the maximum output current to 20mA for the same +100oC case temperature. As a reminder, since the HIP5600 is off during the negative half cycle, the output capacitor must be large enough to supply the maximum load current during this time with some acceptable level of droop. Figure 10 also shows the output ripple voltage, for both a 10mA and 3mA output loads "A2" and "B2", respectively.
Do's And Don'ts
DC Operation 1. Do not exceed the absolute maximum ratings. 2. The HIP5600 requires a minimum output current of 1mA. Minimum output current includes current through RF1. Warning: If there is less than 1mA load current, the output voltage will rise. If the possibility of no load exists, RF1 should be sized to sink 1mA under these conditions. V REF 1.07V RF1 MIN = ------------------ = --------------- = 1k 1mA 1mA
120VRMS, 60Hz I IN B1
A1
20mA/DIV.
B2 VOUT A2 100mV/DIV. 2ms/DIV.
FIGURE 10. AC OPERATION
25 23 21 EFFICIENCY (%) 19 18 16 14 12 10 VIN = 132VRMS VIN = 80VRMS
3. Do not "HOT" switch the input voltage without protecting the input voltage from exceeding 650V. Note: inductance from supplies and wires along with the 0.02F decoupling capacitor can form an under damped tank circuit that could result in voltages which exceed the maximum 650V input voltage rating. Switch arcing can further aggravate the effects of the source inductance creating an over voltage condition. Recommendation: Adequate protection means (such as MOV, avalanche diode, surgector, etc.) may be needed to clamp transients to within the 650V input limit of the HIP5600. 4. Do not operate the part with the input voltage below the minimum 50VDC recommended. Low voltage operation: For input voltages between 0V DC and +5VDC nothing happens (IOUT = 0), for input voltages between +5V DC and +35V DC there is not enough voltage for the pass transistor to operate properly and therefore a high frequency (2MHz) oscillation occurs. For input voltages +35VDC to +50VDC proper operation can occur with some parts.
VOUT = 15.6VDC 0.0 5.0 10.0 LOAD CURRENT (mA) 15.0
FIGURE 11. EFFICIENCY AS A FUNCTION OF LOAD CURRENT
70
HIP5600
5. Warning: the output voltage will approach the input voltage if the adjust pin is disconnected, resulting in permanent damage to the low voltage output capacitor. AC Operation 1. Do not exceed the absolute maximum ratings. 2. The HIP5600 requires a minimum output current of 0.5mA. Minimum output current includes current through RF1. Warning: If there is less than 0.5mA output current, the output voltage will rise. If the possibility of no load exists, RF1 should be sized to sink 0.5mA under these conditions. REF 1.07V RF1 MIN = ------------------ = ----------------- = 2k
0.5mA 0.5m A
minimized by connecting the test equipment ground as close to the circuit ground as possible. CAUTION: Dangerous voltages may appear on exposed metal surfaces of AC powered test equipment.
Application Circuits
+ 50VDC TO 400VDC BUS
HIP5600
V
C1 0.02F
VOUT
ADJ
VIN
+ VOUT
3. If using a laboratory AC source (such as VARIACs or step-up transformers, etc.) be aware that they contain large inductances that can generate damaging high voltage transients when they are switched on or off. Recommendations (1) Preset VARIAC output voltage before applying power to part. (2) Adequate protection means (such as MOV, avalanche diode, surgector, etc.) may be needed to clamp transients to within the 650V input limit of the HIP5600. 4. Do not operate the part with the input voltage below the minimum 50VRMS recommended. Low voltage operation similar to DC operation (reference step 4 under DC operation). 5. Warning: the output voltage will approach the input voltage if the adjust pin is disconnected, resulting in permanent damage to the low voltage output capacitor.
RF1 C3 10F C2 10F RF2
FIGURE 12. DC/DC CONVERTER
The HIP5600 can be configured in most common DC linear regulator applications circuits with an input voltage between 50VDC to 400VDC (above the output voltage) see Figure 12. A 10F capacitor (C2) provides stabilization of the output stage. Heat sinking may be required depending upon the power dissipation. Normally, choose RF1 << VREF / IADJ.
(NOTE 1) 1k HIP5600
General Precautions
Instrumentation Effects Background: Input to output parasitic impedances exist in most test equipment power supplies. The inter-winding capacitance of the transformer may result in substantial current flow (mA) from the equipment power lines to the DC ground of the HIP5600. This "ground loop" current can result in erroneous measurements of the circuits performance and in some cases lead to overstress of the HIP5600. Recommendations for Evaluation of the HIP5600 in the Lab a) The use of battery powered DVMs and scopes will eliminate ground loops. b) When connecting test equipment, locate grounds as close to circuit ground as possible. c) Input current measurements should be made with a noncontact current probe. If AC powered test equipment is used, then the use of an isolated plug is recommended. The isolated plug eliminates any voltage difference between earth ground and AC ground. However, even though the earth ground is disconnected, ground loop currents can still flow through transformer of the test equipment. Ground loops can be 71
ADJ
C1 0.02F
VOUT
VIN
+ VOUT RF1 C3 10F C2 10F RF2
SURGE PROTECTION NOTE 1. 200VRMS - 280VRMS Operation Only
FIGURE 13. AC/DC CONVERTER
The HIP5600 can operate from an AC voltage between 50V RMS to 280VRMS, see Figure 13. The combination of a 1k (2W) input resistor and a V275LA10B MOV provides input surge protection up to 6kV 1.2 x 50s oscillating and pulse waveforms as defined in IEEE/ANSI C62.41.1980. When operating from 120VAC , a V130LA10B MOV provides protection without the 1k resistor. The output capacitor is larger for operation from AC than DC because the HIP5600 only conducts current during the positive half cycle of the AC line. The efficiency is approximately equal to V OUT /V IN (RMS), see Figure 11.
HIP5600
The HIP5600 provides an efficient and economical solution as a start-up supply for applications operating from either AC (50VRMS to 280VRMS) or DC (50VDC to 400V DC). part, the amount of heat sinking (if any) and the ambient temperature. For example; at 400VDC with no heat sink, it will provide 20mA for about 8s, see Figure 8. Power supply efficiency is improved by turning off the HIP5600 when the SMPS is up and running. In this application the output of the HIP5600 would be set via RF1 and RF2 to be about 9V. The tickler winding would be adjusted to about 12V to insure that the HIP5600 is kept off during normal operating conditions.The input current under these conditions is approximately equal to IBIAS. (See Figure 27). The HIP5600 can supply a 450A (20%) constant current. (See Figure 15). It makes use of the internal bias network. See Figure 27 for bias current versus input voltage. With the addition of a potentiometer and a 10F capacitor the HIP5600 will provide a constant current source. IOUT is given by Equation 13 in Figure 16. The HIP5600 can control a P-channel MOSFET or IGPT in a self-oscillating buck regulator. The circuit shown (Figure 17) shows the self-oscillating concept with a P-IGBT driving a dedicated fan load. The output voltage is set by the resistor combination of RF1, RF2, and RF3. Components C3 and RF3 impresses the output ripple voltage across RF1 causing the HIP5600 to oscillate and control the conduction of the P-IGBT. The start-up protection components limit the initial surge current in the P-IGBT by forcing this device into its active region. The snubber circuit is recommended to reduce the power dissipation of the P-IGBT.
HIP5600
+ 50VDC TO 400VDC BUS
VOUT
ADJ
VIN
RF1 RF2
10F
+12V
VOUT PWM
FIGURE 14. START UP CIRCUIT
The HIP5600 has on chip thermal protection and output current limiting circuitry. These features eliminate the need for an in-line fuse and a large heat sink. The HIP5600 can provide up to 40mA for short periods of time to enable start up of a switch mode power supply`s control circuit. The length of time that the HIP5600 will be on, prior to thermal shutdown, is a function of the power dissipation in the
+50VDC TO +400VDC HIP5600 HIP5600 VOUT ADJ VIN 0.02F
VOUT
ADJ
VIN
+20VDC TO +400VDC
R1 IOUT
IOUT
NOTES:
LOAD
1. V OUT Floating 2. Fixed 500A Current Source
IOUT = 1.21V R1
(EQ. 13)
10F
FIGURE 15. CONSTANT 450A CURRENT SOURCE
FIGURE 16. ADJUSTABLE CURRENT SOURCE
72
HIP5600
START-UP PROTECTION
HIP5600
P-IGBT SNUBBER CIRCUIT
VOUT
ADJ
VIN
RF1 + C3 RF2
-
DC FAN
RF3
FIGURE 17. HIGH CURRENT "BUCK" REGULATOR CONCEPT
Typical Performance Curves
OUTPUT VOLTAGE DEVIATION (%) OUTPUT VOLTAGE DEVIATION (%) -0.4 -0.6 -0.8 -1.0 -1.2 -1.4 -1.6 -40 1mA TO 20mA 1mA TO 10mA -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -40 -20 0 25 40 CASE TEMPERATURE (oC) 1mA TO 30mA VIN = 400VDC 60 80 1mA TO 20mA 1mA TO 10mA
1mA TO 30mA -20 0 25 40 60 CASE TEMPERATURE (oC)
VIN = 50VDC 80 100
FIGURE 18. LOAD REGULATION vs TEMPERATURE
85 80 RIPPLE REJECTION (dB) 75 70 65 60 55 50 45 0 NO BYPASS CAPACITOR 10 20 30 40 50 60 70 80 OUTPUT VOLTAGE (V) 90 100 110 1F BYPASS CAPACITOR 10F BYPASS CAPACITOR VIN = 170VDC, IL = 10mA, f = 120Hz, TC = +25 oC
FIGURE 19. LOAD REGULATION VS. TEMPERATURE
90 VIN = 400VDC, IL = 10mA, f = 120Hz, T C = +25oC 80 RIPPLE REJECTION (dB) 70 60 50 40 30 NO BYPASS CAPACITOR
1F BYPASS CAPACITOR 10F BYPASS CAPACITOR
0
50
100 150 200 250 OUTPUT VOLTAGE (V)
300
350
FIGURE 20. RIPPLE REJECTION RATIO (OUTPUT VOLTAGE)
FIGURE 21. RIPPLE REJECTION RATIO (OUTPUT VOLTAGE)
73
HIP5600 Typical Performance Curves
85 80 RIPPLE REJECTION (dB) 75 70 65 60 55 50 45 1 10 1F BYPASS CAPACITOR NO BYPASS CAPACITOR 100 1k 10k 100k INPUT FREQUENCY (Hz) 1M 10M 10F BYPASS CAPACITOR
(Continued)
85 80 RIPPLE REJECTION (dB) 75 70 65 60 55 50 45 1 1F BYPASS CAPACITOR NO BYPASS CAPACITOR 10 100 1k 10k 100k 1M 10M VIN = 400VDC , IL = 10mA, VOUT = 15V, TC = +25 oC 10F BYPASS CAPACITOR
VIN = 170VDC, IL = 10mA, VOUT = 15V, TC = +25oC
INPUT FREQUENCY (Hz)
FIGURE 22. RIPPLE REJECTION RATIO (INPUT FREQUENCY)
FIGURE 23. RIPPLE REJECTION RATIO (INPUT FREQUENCY)
85
85 80 RIPPLE REJECTION (dB) 75 70
VIN = 170VDC, VOUT = 10mA, f = 120Hz, TC = +25oC RIPPLE REJECTION (dB) (REFERENCE FIGURE 3) 80 75 70
VIN = 400VDC, VOUT = 10mA, f = 120Hz, TC = +25oC (REFERENCE FIGURE 3)
1F BYPASS CAPACITOR 65 60 55 50 NO BYPASS CAPACITOR 10F BYPASS CAPACITOR
1F BYPASS CAPACITOR 65 60 NO BYPASS CAPACITOR 55 10F BYPASS CAPACITOR
0
5
10 15 20 25 OUTPUT CURRENT (mA)
30
35
50
0
5
10 15 20 25 OUTPUT CURRENT (mA)
30
35
FIGURE 24. RIPPLE REJECTION RATIO (OUTPUT CURRENT)
FIGURE 25. RIPPLE REJECTION RATIO (OUTPUT CURRENT)
520 510 100 OUTPUT IMPEDANCE () C2 = 0.01F, C3 = 0F IBIAS (A) 500 490 480 470 460 450 C2 = 10F, C3 = 10F 440 430 0.1 10 100 1K 10K FREQUENCY (Hz) 100K 1M 420 50 100 200 300 INPUT VOLTAGE (VDC) 400 TC = +25 oC TC = -40oC IOUT = 0 TC = +100oC
10.0 C2 = 10F, C3 = 0F
1.0
FIGURE 26. OUTPUT IMPEDANCE
FIGURE 27. IBIAS vs INPUT VOLTAGE
74
HIP5600 Typical Performance Curves
C3 = 10F C3 = 10F C3 = 0F 400V INPUT VOLTAGE 100V 0V VOUT = 15VDC IL= 5mA TJ = +25oC OUTPUT CURRENT 100V/DIV C3 = 0F 10mA 5mA 0mA VIN = 400VDC VOUT = 15V TJ = +25 oC 5mA/DIV VOUT 15V
(Continued)
100mV/DIV
VOUT 15V
20mV/DIV
T = 100ms/DIV
T= 100ms/DIV
FIGURE 28. LINE TRANSIENT RESPONSE
FIGURE 29. LOAD TRANSIENT RESPONSE
1.21 1.20 REFERENCE VOLTAGE (V) 1.19 1.18 1.17 1.16 1.15 1.14 1.13 1.12 1.11 1.10 -40 -20 0 25 40 60 CASE TEMPERATURE (oC) 80 100 20mA 30mA 1mA 5mA 10mA VIN = 50VDC REFERENCE VOLTAGE (V)
1.25 VIN = 400VDC 1.20 1mA 5mA
1.15 10mA 1.10 20mA 1.05 30mA -40 -20 0 25 40 60 80
1.00
CASE TEMPERATURE (oC)
FIGURE 30. REFERENCE VOLTAGE vs TEMPERATURE
FIGURE 31. REFERENCE VOLTAGE vs TEMPERATURE
1.20 1.19 REFERENCE VOLTAGE (V) 1.18 1.17 1.16 1.15 1.14 1.13 1.12 1.11 1.10 1.09 1.08 0 100 200 300 INPUT VOLTAGE (VDC) 400 TC = +100oC TC = +25o C IOUT = 10mA REFERENCE VOLTAGE (V) TC = -40oC
1.20 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 0 100 30mA 1mA 5mA 10mA
20mA
200 300 INPUT VOLTAGE (VDC)
400
FIGURE 32. REFERENCE VOLTAGE vs INPUT VOLTAGE
FIGURE 33. REFERENCE VOLTAGE vs VIN; CASE TEMPERATURE OF +25oC
75
HIP5600 Typical Performance Curves
80 75 ADJ CURRENT (A) 70 65 60 30mA 55 50 45 20mA VIN = 50VDC 1mA ADJ CURRENT (A) 70 65 1mA 60 55 50 45 -40 -20 0 25 40 60 CASE TEMPERATURE (oC) 80 100 30mA 20mA 5mA 10mA
(Continued)
80 VIN = 400VDC 75
-40
-20
0 25 40 CASE TEMPERATURE (oC)
60
80
FIGURE 34. IADJ vs TEMPERATURE
775 770 LOAD CURRENT (A) TC = +25oC CURRENT (A) 765 760 TC = +100oC 755 750 745 0 1500 2000
FIGURE 35. IADJ vs TEMPERATURE
VIN = 100VDC TC = 25oC
MINIMUM LOAD CURRENT 1000 IIN 500 IOUT IADJ 1 2 3 VOUT - VADJ (VDC) 4 5 BIAS CURRENT
50
100
200 INPUT VOLTAGE (VDC)
300
400
FIGURE 36. MINIMUM LOAD CURRENT vs V IN
55 OUTPUT CURRENT (mA) 50 45 40 35 30 25 20 50 TC = +100oC 100 150 200
FIGURE 37. TERMINAL CURRENTS vs FORCED VREF
TC = -40 oC
TC = +25oC
250
300
350
400
INPUT-OUTPUT (VDC)
FIGURE 38. CURRENT LIMIT vs TEMPERATURE
76
HIP5600 Evaluation Boards
SA = 22oC/W
HEAT SINK
3.25"
F1
ADJ VOUT RF1 RS VIN MOV
VIN
C2 C1 RF2 C3 VOUT
+ -
HIP5600 EVALUATION BOARD 3.25" 3.25"
FIGURE 39. EVALUATION BOARD (TOP)
FIGURE 40. EVALUATION BOARD METAL MASK (BOTTOM)
HEAT SINK
3.25"
ADJ VOUT
VIN
3.25"
HIP5600
+ VIN VOUT HIP5600 EVALUATION BOARD 3.25"
FIGURE 41. EVALUATION BOARD METAL MASK (TOP)
77
HIP5600 Single-In-Line Plastic Packages (SIP)
OP Q H1 D E A F
Z3.1B
3 LEAD PLASTIC SINGLE-IN-LINE PACKAGE INCHES SYMBOL A b b1 c1 D E e e1 F MIN 0.140 0.015 0.045 0.014 0.560 0.380 0.090 0.190 0.020 0.230 0.080 0.500 0.139 0.100 MAX 0.190 0.040 0.070 0.022 0.650 0.420 0.110 0.210 0.055 0.270 0.115 0.580 0.250 0.161 0.135 MILLIMETERS MIN 3.56 0.38 1.14 0.36 14.23 9.66 2.29 4.83 0.51 5.85 2.04 12.70 3.53 2.54 MAX 4.82 1.02 1.77 0.56 16.51 10.66 2.79 5.33 1.39 6.85 2.92 14.73 6.35 4.08 3.43 NOTES 1 1 2 2 3 1 Rev. 1 2/95
L1
b1 b c1
L
1
2
3 J1
e e1 NOTES:
H1 J1 L L1 OP Q
1. Lead dimension and finish uncontrolled in zone L1. 2. Position of lead to be measured 0.250 inches (6.35mm) from bottom of dimension D. 3. Position of lead to be measured 0.100 inches (2.54mm) from bottom of dimension D. 4. Controlling dimension: INCH.
78


▲Up To Search▲   

 
Price & Availability of HIP560002

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X